Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38667734

RESUMEN

Background: In patients with an implantable cardioverter-defibrillator (ICD) for secondary prevention, sex differences may exist in clinical outcomes. We sought to investigate sex differences in appropriate ICD therapy, appropriate and inappropriate shock, and all-cause mortality in this patient population. Methods: A total of 257 patients who received an ICD for a secondary prevention indication in the University Medical Centre Groningen (UMCG) between 1 January 2012 and 31 December 2018 were retrospectively included in a consecutive manner. Appropriate ICD therapy, comprising shock and antitachycardia pacing (ATP) for ventricular fibrillation (VF) or ventricular tachycardia (VT), was the primary outcome. Results: The patient population included 257 patients, of whom 45 (18%) were women and 212 (82%) were men. The median of the age was 64 (interquartile range (IQR) 53-72) years. During follow-up (median duration 6.2 (IQR 4.8-7.8) years), first appropriate device therapy took place in 10 (22%) patients for women and 85 (40%) patients for men. Female sex was negatively associated with the rate of appropriate ICD therapy, univariably (hazard ratio (HR) 0.48 [95% confidence interval (CI) 0.25-0.93]; p = 0.030) and multivariably (HR 0.44 [95% CI 0.20-0.95]; p = 0.036). Conclusions: Women with secondary prevention ICDs were less likely than men to receive appropriate ICD therapy.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38430087

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.

3.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38340118

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Sistema de Registros , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Europa (Continente) , Resultado del Tratamiento , Recurrencia , Reoperación/estadística & datos numéricos
4.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38385529

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS: FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION: In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION: Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula , Venas Pulmonares , Femenino , Humanos , Masculino , Antiarrítmicos , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Constricción Patológica/cirugía , Fístula/cirugía , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Taquicardia/cirugía , Resultado del Tratamiento , Persona de Mediana Edad , Anciano
5.
Open Heart ; 10(2)2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38135341

RESUMEN

BACKGROUND: Sex differences in atrial fibrillation (AF) are observed in terms of comorbidities, symptoms, therapies received, AF progression and cardiovascular complications. METHODS: We assessed the differences in prevalence and the determinants of AF progression, as well as the clinical characteristics and quality of life (QoL), between women and men with paroxysmal AF included in the RACE V (Reappraisal of Atrial Fibrillation: Interaction between hyperCoagulability, Electrical remodeling, and Vascular Destabilisation in the Progression of AF) study. At baseline, extensive phenotyping was done. To assess AF progression, implantable loop recorder (ILR) monitoring was used throughout follow-up. AF progression was defined as (1) progression to persistent or permanent AF or (2) progression of paroxysmal AF (>3% burden increase). RESULTS: 417 patients were included, 179 (43%) of whom were women. Women were older (median 67 years vs 63 years, p<0.001), less often had coronary artery disease (n=11 (6%) vs n=36 (16%), p=0.003), had more obesity (n=57 (32%) vs n=50 (21%), p=0.013), had less epicardial and pericardial fat (median 144 (interquartile range [IQR] 94-191) mL vs 199 (IQR 146-248) mL, p<0.001; and median 89 (ICQ 61-121) mL vs 105 (IQR 83-133) mL, p<0.001, respectively) and had more impaired left atrial function. The median follow-up was 2.2 (1.6-2.8) years. 51 of 417 patients (5.5% per year) showed AF progression (15/179 (8.4%) women and 36/238 (15.1%) men, p=0.032). Multivariable analysis showed tissue factor pathway inhibitor, N-terminal prohormone brain natriuretic peptide (NT-proBNP) and PR interval being associated with AF progression in women and factor XIIa:C1 esterase, NT-proBNP and proprotein convertase subtilisin/kexin type 9 in men. QoL was not different between sexes. CONCLUSION: Despite older age, the incidence of AF progression was lower in women. Parameters associated with AF progression varied in part between sexes, suggesting different underlying pathophysiological mechanisms.


Asunto(s)
Fibrilación Atrial , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Calidad de Vida
6.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37910101

RESUMEN

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Asunto(s)
Fibrilación Atrial , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adolescente , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Estudios de Cohortes , Factores Sexuales , Resultado del Tratamiento
9.
J Clin Med ; 12(13)2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37445514

RESUMEN

In this study, we sought to investigate the occurrence of appropriate implantable cardioverter-defibrillator (ICD) therapies and inappropriate shocks in secondary prevention ICD recipients with ventricular arrhythmia of unclear cause and ventricular arrhythmia in the context of underlying heart disease. In this retrospective study, consecutive patients with an ICD implanted for secondary prevention in the University Medical Center Groningen (UMCG), the Netherlands between 1 January 2012 and 31 December 2018 were included. Patients were classified as having ventricular arrhythmia of unclear cause if no clear cause was found which could explain the index ventricular arrhythmia. The primary outcome was appropriate ICD therapy. The study population consisted of 257 patients. In 220 patients, an underlying heart disease could be identified as the cause of ventricular arrhythmia, while 37 patients had an unclear cause of ventricular arrhythmia. The median age was 64 years (interquartile range (IQR) 53-72 years). Forty-five (18%) patients were women. During a median duration of follow-up of 6.2 years (IQR 4.8-7.8 years), appropriate ICD therapy occurred in 95 (37%) patients. This number was 90 (41%) in the group with a clear etiology and 5 (14%) in the group with an unclear etiology. In multivariable analysis, index ventricular arrhythmia of unclear cause was associated with fewer appropriate ICD therapies (HR 0.37 [95% CI 0.14-0.99]; p = 0.048), as well as an increased risk of inappropriate ICD shocks (HR 3.71 [95% CI 1.17-11.80]; p = 0.026). Index ventricular arrhythmia of unclear cause was significantly associated with fewer appropriate ICD therapies.

10.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37379528

RESUMEN

AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Poria , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Venas Pulmonares/cirugía , Recurrencia
11.
J Interv Card Electrophysiol ; 66(7): 1729-1737, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37195355

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is a novel ablation technology recently adopted in the treatment of atrial fibrillation (AF). Currently, little is known about the durability of PFA ablation lesions. METHODS: We investigated patients who underwent redo-ablation due to recurrent AF/atrial-flutter or tachycardia (AFL/AT) following PVI with PFA. We report electrophysiological findings and ablation strategy during redo-ablation. RESULTS: Of 447 patients undergoing index PVI with PFA, 14 patients (age: 61.9±10.8 years; 7 (50.0%) males; left atrial volume index (n=10): 39.4±14.6 mL/m2) were referred for redo-ablation. Initial indication was paroxysmal-AF in 7 patients, persistent-AF in 6 and long-standing-persistent-AF in one patient. Mean time-to-recurrence was 4.9±1.9 months. Three patients received additional posterior-wall-isolation during index PFA. Twelve (85.7%) patients suffered AF recurrence and 5/12 had concomitant AFL. In the remaining 2 patients, one had a (box-dependent) AFL, and one had an atypical AT. No patients had all PVs reconnected. Reconnection in zero, one, two or three PVs was found in 35.7%, 21.4%, 14.3%, and 28.6% of patients, respectively. All 7 patients with zero or one reconnection with AF recurrence received additional/repeat posterior-wall-isolation during re-ablation, while in the others, PVs were re-isolated. Patients with only AFL/AT had no reconnection of PVs, and the substrate was successfully ablated. CONCLUSIONS: Durable PVI (all PV's isolated) was observed in over one-third of patients at re-do. The predominant recurrent arrhythmia following PVI-only was AF. Concomitant (35.7%) or isolated (14.3%) AFL/AT recurrence was observed in 50% of patients.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Atrios Cardíacos/cirugía , Aleteo Atrial/cirugía , Electrofisiología Cardíaca , Ablación por Catéter/métodos , Recurrencia , Resultado del Tratamiento
12.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
14.
Front Cardiovasc Med ; 9: 959186, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36426226

RESUMEN

Introduction: Pulsed field ablation (PFA) was recently introduced for the treatment of symptomatic atrial fibrillation (AF) with the claim of selectively ablating the myocardium while sparing surrounding tissues. We present our initial experience with a PFA catheter for pulmonary vein isolation (PVI) and describe procedural findings and peri-procedural safety of the first 100 patients. Materials and methods: We investigated 100 patients treated for symptomatic AF using the FARAWAVE PFA catheter (Farapulse, Menlo Park, CA, USA) between July 2021 and March 2022. Procedure workflow and electrophysiological findings at the time of ablation, peri-procedural complications, and operator learning curves are described. Results: The mean age of patients was 62.9 ± 9.4 years, 62% were male subjects and 80% had paroxysmal AF. The median CHA2DS2-VASc score was 1.5 (IQR: 1.0-2.0) and the mean left atrial volume index was 35.7 ± 9.6 ml/m2. In 88 (88%) patients, PVI alone was performed and in 12 (12%) patients additional ablation of the posterior wall was performed. 3D-electroanatomic mapping was performed in 18 (18%) patients. Procedures without mapping lasted for 52.3 ± 16.6 min. The mean number of applications per pulmonary vein (PV) was 8.1 ± 0.6. In all patients (100%), all PVs were confirmed to be isolated. The learning curves of the two operators who performed > 20 procedures showed a negligible variation of performance over time and practice did not significantly predict procedure time [Operator 1 (senior): R 2 = 0.034, p = 0.35; Operator 2 (junior): R 2 = 0.004, p = 0.73]. There was no difference between the procedure times between senior and junior operators (Operator 1: 46.9 ± 9.7 min vs. Operator 2: 45.9 ± 9.9 min; p = 0.73). The only complications observed were two cases of bleeding at the site of percutaneous access. Conclusion: Our initial experience shows that use of the PFA catheter for pulmonary vein isolation (PVI) is safe, fast, and easy to learn.

15.
BMJ Open ; 12(11): e063359, 2022 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-36368743

RESUMEN

OBJECTIVES: Pulmonary vein isolation (PVI) is widely accepted as an effective and safe treatment for symptomatic atrial fibrillation (AF). However, data on sex-related differences and associations with clinical outcome and safety of PVI with cryoballoon ablation are limited. We sought to compare sexrelated efficacy and safety of cryoballoon ablation and identify sex-related associations with clinical outcomes. METHODS AND RESULTS: We included 650 consecutive patients with AF undergoing PVI with cryoballoon ablation at our institution between 2013 and 2017. The efficacy outcome was the first documented recurrence (>30 s) of AF, atrial flutter or atrial tachycardia (AF/AT) or repeat ablation during follow-up, after a 90-day blanking period. The safety outcome was the incidence of periprocedural complications. Mean age of the population was 58±10, and 210 (32.3%) patients were women. Women were older, had a higher body mass index, had more renal dysfunction and less coronary artery disease as compared with men. The rate of AF/AT recurrence was similar between women and men at 12-month follow-up (27.6% vs 24.8%, p=0.445). The incidence of periprocedural complications was higher in women (12.9% vs 4.6%; p<0.001), specifically groin haematomas and phrenic nerve palsy. On multivariate analysis, left atrial volume index (adjusted OR 1.05, 95% CI 1.00 to 1.10; p=0.032) was associated with the incidence of procedural complications in women. For men, no relation with complications could be found. CONCLUSION: The efficacy of cryoballoon ablation was similar between women and men; however, women had a higher risk of procedural complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Masculino , Humanos , Femenino , Venas Pulmonares/cirugía , Fibrilación Atrial/epidemiología , Criocirugía/métodos , Resultado del Tratamiento , Estudios de Cohortes , Recurrencia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
16.
Heart ; 2022 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-35858774

RESUMEN

OBJECTIVE: Atrial fibrillation (AF) often progresses from paroxysmal AF (PAF) to more permanent forms. To improve personalised medicine, we aim to develop a new AF progression risk prediction model in patients with PAF. METHODS: In this interim-analysis of the Reappraisal of AF: Interaction Between HyperCoagulability, Electrical Remodelling, and Vascular Destabilisation in the Progression of AF study, patients with PAF undergoing extensive phenotyping at baseline and continuous rhythm monitoring during follow-up of ≥1 year were analysed. AF progression was defined as (1) progression to persistent or permanent AF or (2) progression of PAF with >3% burden increase. Multivariable analysis was done to identify predictors of AF progression. RESULTS: Mean age was 65 (58-71) years, 179 (43%) were female. Follow-up was 2.2 (1.6-2.8) years, 51 of 417 patients (5.5%/year) showed AF progression. Multivariable analysis identified, PR interval, impaired left atrial function, mitral valve regurgitation and waist circumference to be associated with AF progression. Adding blood biomarkers improved the model (C-statistic from 0.709 to 0.830) and showed male sex, lower levels of factor XIIa:C1-esterase inhibitor and tissue factor pathway inhibitor, and higher levels of N-terminal pro-brain natriuretic peptide, proprotein convertase subtilisin/kexin type 9 and peptidoglycan recognition protein 1 were associated with AF progression. CONCLUSION: In patients with PAF, AF progression occurred in 5.5%/year. Predictors for progression included markers for atrial remodelling, sex, mitral valve regurgitation, waist circumference and biomarkers associated with coagulation, inflammation, cardiomyocyte stretch and atherosclerosis. These prediction models may help to determine risk of AF progression and treatment targets, but validation is needed. TRIAL REGISTRATION NUMBER: NCT02726698.

17.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35647644

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto Joven
19.
Am Heart J ; 250: 45-56, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35537503

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) provides an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). In patients with a long-term or permanent contraindication for OAC randomized controlled trial (RCT) data is lacking. STUDY OBJECTIVES: To assess the efficacy and safety of LAAO in AF patients who are ineligible to use OAC. The co-primary efficacy endpoint is (1) time to first occurrence of stroke (ischemic, hemorrhagic, or undetermined) and (2) time to first occurrence of the composite of stroke, transient ischemic attack (TIA), and systemic embolism (SE). The primary safety endpoint is the 30-day rate of peri-procedural complications. STUDY DESIGN: This is a multicenter, investigator-initiated, open-label, blinded endpoint (PROBE), superiority-driven RCT. Patients with AF, a CHA2DS2-VASc score ≥2 for men and ≥3 for women and a long-term or permanent contraindication for OAC will be randomized in a 2:1 fashion to the device- or control arm. Patients in the device arm will undergo percutaneous LAAO and will receive post-procedural dual antiplatelet therapy (DAPT) per protocol, while those in the control arm will continue their current treatment consisting of no antithrombotic therapy or (D)APT as deemed appropriate by the primary responsible physician. In this endpoint-driven trial design, assuming a 50% lower stroke risk of LAAO compared to conservative treatment, 609 patients will be followed for a minimum of 1 and a maximum of 5 years. Cost-effectiveness and budget impact analyses will be performed to allow decision-making on reimbursement of LAAO for the target population in the Netherlands. SUMMARY: The COMPARE LAAO trial will investigate the clinical superiority in preventing thromboembolic events and cost-effectiveness of LAAO in AF patients with a high thromboembolic risk and a contraindication for OAC use. NCT TRIAL NUMBER: NCT04676880.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Anticoagulantes , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Femenino , Humanos , Masculino , Nivel de Atención , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/prevención & control , Tromboembolia/etiología , Tromboembolia/prevención & control , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...